VOC sensor - Volatile Organic Compounds | Aeroqual (2024)

Measurements

Aeroqual designs and delivers monitors that measure VOCs. Choose from our perimeter or handheld air monitoring range.

Here we cover VOC measurement principles, specifications and performance.

Overview of VOCs

Volatile Organic Compounds (VOCs) is the name given to a group of organic compounds which can exist as a gas in the atmosphere. VOCs are not listed among the six criteria health pollutants cited by the US EPA. However, the effects of VOC exposure are becoming more understood and demands for ambient VOC monitoring are increasing.

VOC sensor - Volatile Organic Compounds | Aeroqual (1)

Perimeter air quality monitors

The VOC analyzer modules feature in our perimeter air quality monitors: AQS 1 Air Quality Monitor and AQM 65 Monitoring Station.

Two measurement options:

  • VOCs High Range (0-30 ppm)

  • VOCs Low Range (0-500 ppb)

VOC module measurement principle

The sensor used in the VOC module is a photoionization detector (PID) sensor. The sensor generates an electrical current proportional to the concentration of gas that comes in to contact with the sensor. The current generated differs depending on the organic compound, so the PID module is only quantitative towards the compound it is calibrated with; in most applications this is isobutylene.

The VOC module is sensitive to a wide range of VOCs, including benzene and toluene, though not methane, ethane, propane, formaldehyde, or low molecular weight alcohols.

The patented VOC module design cycles between reading the sample air and reading air that has been filtered using a proprietary scrubber. This negates the effect of ambient air humidity changes, known to reduce the performance of a PID-based VOC measurement. The module has a controlled flow rate. The flow rate is determined by a flow control orifice on the exhaust side of the sensor and measured at the inlet to the sensor module (expected to be approximately 60 mL min-1).

The sensor current in converted to a voltage and the voltage is measured and used to calculate the VOC concentration using a proprietary algorithm approximately once per minute.

VOC module specifications and performance

The VOC module performance specifications are given in the table below.

VOC Low Range

VOC High Range

Range

0-500 ppb

0-30 ppm

Display Resolution

0.1 ppb

0.01 ppm

Noise: Zero; Span (% of reading)

<1 ppb; 1%

<0.1 ppm; 1%

Limit of Detection

<1 ppb

<0.1 ppm

Precision

2% of reading or 1 ppb

2% of reading or 0.05 ppm

Linearity (% of FS)

1%

2%

24 hr Drift: Zero; Span (% of FS)

1 ppb; 1%

0.1 ppm; 1%

VOC module calibration and traceability

Just like a regulatory VOC analyzer using gas chromatography, the VOC module can be field calibrated using standard calibration equipment and reference gases. This ensures the module calibration is fully traceable to NIST primary standards.

The VOC module factory calibration is achieved using a zero-air source, a certified calibration gas standard and a certified gas dilution calibrator. Isobutylene is the recommended calibration gas to be used for the AQM 65 VOC module. The Aeroqual AirCal 1000 or 8000 systems can be used to calibrate the VOC module in the field.

Calibration frequency will be dependent on the user’s data quality objectives and Quality Assurance Project Plan (QAPP), but based on the low rate of field drift the recommended calibration frequency is 1-3 months.

To demonstrate, multi-point gas test at known concentrations was carried out using the equipment described above. The gas test is split into low range and high range. The module shows good linearity (R2 = 0.99) over the entire concentration range studied.

VOC sensor - Volatile Organic Compounds | Aeroqual (2)

VOC module high range time series plot

VOC module high range scatter plot of data with linear regression and coefficient of determination

VOC sensor - Volatile Organic Compounds | Aeroqual (4)

VOC module low range time series plot

VOC sensor - Volatile Organic Compounds | Aeroqual (5)

VOC module low range scatter plot of data with linear regression and coefficient of determination

Interferances

The VOC module response to other ambient air pollutants is documented in the table below.

Pollutant

Test concentration / ppm

Typical module response / ppm

Isobutylene

1.0

1.0

Benzene

0.1

0.2

CO

1.0

No response

NO2

0.1

No response

O3

0.1

No response

SO2

0.1

No response

Ethylene

0.5

No response

H2S

0.1

0.025

PID sensors respond to a wide range of VOCs but are calibrated against isobutylene. Response factors for other target gases are used to convert the isobutylene equivalent reading to that of the target gas. PID response factors for a wide range of target gases are well documented and available via Aeroqual.

VOC module expected lifetime

The non-catalytic chemical scrubber has an expected life of 2 to 3 years.

The internal solenoid has an expected life of 2 to 3 years. The VOC sensor contains a lamp which has a limited lifetime. The expected lifetime of the lamp is approximately 200 days of continuous operation. The VOC module can be sent back to Aeroqual for a lamp replacement or replaced by a qualified technician using a lamp replacement kit, available for purchase from Aeroqual.

VOC sensor - Volatile Organic Compounds | Aeroqual (6)

Handheld air monitors and fixed indoor monitors with VOC sensors

The VOC sensor heads feature in our handheld air quality monitors: Ranger, S Series, and fixed indoor Series 900 air monitors.

Five measurement options:

  • VOC GSS Sensor 0-25 ppm

  • VOC GSS Sensor 0-500 ppm

  • VOC PID Sensor 0-30 ppm

  • VOC PID Sensor 0-2000 ppm

  • NMHC GSS Sensor 0-25 ppm

VOC sensor head measurement principle

Aeroqual offers three different types of VOC sensor technology for measurement, including a sensor head for non-methane hydrocarbons (NMHC).

Technology

Sensor Type

Target Gas

VOC PID

Photoionization detection 10.6 eV

VOC

VOC GSS

Gas sensitive semiconductor

VOC

NMHC GSS

Gas sensitive semiconductor

NMHC

These sensors respond to a broad range of VOCs although they each display a unique sensitivity to certain VOCs or classes of hydrocarbons. None of the sensor heads respond to methane.

The VOC PID sensor heads contain a photoionization detector (PID). This sensor generates an electrical current proportional to the concentration of gas that comes in to contact with the sensor. The VOC PID sensor head is sensitive to a wide range of VOCs, including benzene and toluene, but not methane, ethane, propane, formaldehyde, or low molecular weight alcohols.

The VOC GSS and NMHC GSS sensor heads contain a gas sensitive semiconductor (GSS) sensor. These sensors are manufactured by Aeroqual. The sensing material for both sensor heads is a p-type semiconductor, whose resistance increases when the sensing layer is exposed to VOCs. The sensor resistance is used to calculate concentration using a proprietary algorithm.

VOC sensor - Volatile Organic Compounds | Aeroqual (7)

VOC sensor head sensitivity diagram

VOC GSS sensor head specifications

The table below contains the VOC GSS sensor head specifications. The NMHC 0-25 ppm sensor head is designed for outdoor environmental monitoring. The VM 0-25 ppm sensor is designed for both outdoor environmental monitoring and indoor air quality. The VP 0-500 ppm sensor head is designed for industrial health and safety air monitoring.

Sensor code

VM

VP

NMHC

Sensor type

GSS

GSS

GSS

Range (ppm)

0-25

0-500

0-25

Detection limit (ppm)

0.1

1

0.1

Accuracy of factory calibration

<±0.1 ppm + 10%

<±5 ppm + 10%

<±0.1 ppm + 10%

Display resolution (ppm)

0.1

1

0.1

Response time (seconds)

60

30

60

PID Sensor head specifications

The table below contains the VOC PID sensor specifications. The VOC 0-30 ppm sensor head is designed for both outdoor environmental monitoring and indoor air quality. The VOCH 0-2000 ppm sensor head is designed for industrial health and safety air monitoring.

Sensor code

VOC

VOCH

Sensor type

PID

PID

Range

0-30 ppm

0-2000 ppm

Detection limit

0.01 ppm

0.1 ppm

Accuracy of factory calibration

<±0.02 ppm + 10%

<±0.2 ppm + 10%

Resolution

0.01 ppm

<1000 ppm; 0.1

>1000 ppm; 1

Response time

30 seconds

30 seconds

VOC sensor head calibration

All the VOC sensor heads are calibrated at the Aeroqual factory using isobutylene. However, for both VOC sensor types, the response differs depending on the organic compound. Response factors for other target gases can be used to convert the isobutylene equivalent reading to that of the target gas. Response factors for a variety of target gases are available via Aeroqual. If the atmosphere being measured contains a mixture of hydrocarbons (this is likely when measuring outdoor ambient air), the measurement is quantitative only.

Products that have VOC sensors

The following products measure VOCs, as well as particulate matter and gaseous pollutants in real-time.

VOC sensor - Volatile Organic Compounds | Aeroqual (8)

AQS 1 Air Quality Monitor

Measure VOCs, particulate matter and up to 2 other gases.

VOC sensor - Volatile Organic Compounds | Aeroqual (9)

AQM 65 Ambient Air Monitoring Station

Measure VOCs, and up to 20 total gaseous and particulate pollutants within a thermally controlled enclosure.

VOC sensor - Volatile Organic Compounds | Aeroqual (10)

Ranger - Portable Air Quality Monitor

Measure VOCs and up to 15 common indoor and outdoor pollutants with swappable sensor heads.

VOC sensor - Volatile Organic Compounds | Aeroqual (11)

Series 900 – Fixed VOC Monitor

Compatible with a range of swappable gas sensor heads, including VOCs.

Articles

See more articles

Case Study - Remediation250 Water Street NYSDECRead MoreBlog - RemediationPerimeter Air Monitoring Plan Requirements – What All Site Remediators Need to KnowRead MoreCase Study - RemediationMontana Pole and Treating Plant Superfund SiteRead More

Our VOC advanced monitoring systems deliver hyper-local data and real-time alerts, giving you actionable data to make the decisions that matter.

Let's talk

VOC sensor - Volatile Organic Compounds | Aeroqual (2024)
Top Articles
Latest Posts
Article information

Author: Duncan Muller

Last Updated:

Views: 5767

Rating: 4.9 / 5 (59 voted)

Reviews: 90% of readers found this page helpful

Author information

Name: Duncan Muller

Birthday: 1997-01-13

Address: Apt. 505 914 Phillip Crossroad, O'Konborough, NV 62411

Phone: +8555305800947

Job: Construction Agent

Hobby: Shopping, Table tennis, Snowboarding, Rafting, Motor sports, Homebrewing, Taxidermy

Introduction: My name is Duncan Muller, I am a enchanting, good, gentle, modern, tasty, nice, elegant person who loves writing and wants to share my knowledge and understanding with you.